Title 49 · TransportationTransportation
Changes to 49 U.S.C. § 60110
S. 2975 · Pipeline Integrity, Protection, and Enhancement for Leveraging Investments in the Nation's Energy to assure Safety Act of 2025 · Engrossed The official text as one chamber (House or Senate) passed it.
PIPELINE Safety Act of 2025
Passed the Senate · step 3 of 5
49 U.S.C. § 60110 Excess flow valves
1 change the bill asks for here, 1 carried out
- Carried out:
Section 60110 of title 49, United States Code, is amended by adding at the end the following:
(f) Fire shutoff valves or equivalent technology.— (1) Definitions.— In this subsection: (A) Equivalent technology.— The term “equivalent technology” means any technology that— (i) is not an excess flow valve; and (ii) meets the performance standard of shutting off gas on a …
§ 60110(d)–(f)
Start of § 60110 to (c)(2) unchanged ·
(d) Report.— If the Secretary decides under subsection (b) of this section that there are no circumstances under which an operator must install excess flow valves, the Secretary shall submit to Congress a report on the reasons for the decision not later than 30 days after the decision is made.
(e) Performance Standards.— Not later than April 24, 1994, the Secretary shall develop standards for the performance of excess flow valves used to protect lines in a natural gas distribution system. The Secretary may adopt industry accepted performance standards in order to comply with the requirement under the preceding sentence. The standards shall be incorporated into regulations the Secretary prescribes under this section. All excess flow valves shall be installed according to the standards.
(f) [inserted: Fire shutoff valves or equivalent technology.—]
(1) [inserted: Definitions.—] [inserted: In this subsection:]
(A) [inserted: Equivalent technology.—] [inserted: The term “equivalent technology” means any technology that—]
(i) [inserted: is not an excess flow valve; and]
(ii) [inserted: meets the performance standard of shutting off gas on a service line of a distribution system to a dwelling or other building in the event of a fire.]
(B) [inserted: Fire-first ignition.—] [inserted: The term “fire-first ignition” means an occurrence in which a fire originating from a foreign source causes a natural gas system to fail, release, or ignite.]
(C) [inserted: Fire safety valve.—] [inserted: The term “fire safety valve” means—]
(i) [inserted: a fire shutoff valve; and]
(ii) [inserted: any equivalent technology.]
(D) [inserted: Fire shutoff valve.—] [inserted: The term “fire shutoff valve” means a spring-loaded plug that is held in place by a fusible link that—]
(i) [inserted: is made of a low-melting-point alloy;]
(ii) [inserted: is attached to a gas source; and]
(iii) [inserted: melts when exposed to fire, causing the spring-loaded plug to close, shutting off the gas to a dwelling or other building connected to a service line of a distribution system.]
(2) [inserted: Study.—]
(A) [inserted: In general.—] [inserted: Not later than 2 years after the date of enactment of this subsection, the Secretary shall complete a study on the effectiveness of fire safety valves in order to determine the ability of fire safety valves to improve public safety through mitigation of secondary ignitions, such as fire-first ignitions.]
(B) [inserted: Requirements.—] [inserted: The study under subparagraph (A) shall evaluate—]
(i) [inserted: various scenarios and applications for deploying fire safety valves;]
(ii) [inserted: the current incidence of fire-first ignition of natural gas distribution pipelines;]
(iii) [inserted: anticipated reduction of fire-first ignition risk under various fire safety valve deployment scenarios, including—]
(I) [inserted: lowering the likelihood of gas ignition; and]
(II) [inserted: lowering the impact and damage of fire-first ignition incidents;]
(iv) [inserted: the long-term durability, construction, and effectiveness of fire safety valves; and]
(v) [inserted: the commercial availability of fire safety valves for the pipeline industry.]
(3) [inserted: Rulemaking.—] [inserted: After completing the study described in paragraph (2), the Secretary may prescribe risk-based standards on the circumstances under which an operator of a natural gas distribution system shall be required to install fire shutoff valves or equivalent technologies in the system.]